OTDR NISSAI XB430-C1F2 1650nm 26dB (with Filter for 1650nm) (VFL, LS, OPM, RT, RS)

On demand
SKU
OTDR-NISSXB430C1F226
€0.00 net €0.00 Incl. VAT 23%
 

OTDR NISSAI XB430-C1F2 1650nm 26dB (with Filter for 1650nm) (VFL, LS, OPM, RT, RS) a measuring device that is well suited for fiber optic measurements and fault detection in optical network construction and communication systems. It is characterized by ease of use, multifunctionality and compact size.


Main features:
- SM wavelength: 1650nm, 26dB, with a filter at 1650nm wavelength,
- Universal 2.5mm optical port for VFL and OPM connectors,
- FC/UPC optical port (can be changed to SC/UPC) for the 1650nm OTDR connector,
- Designed for operation in harsh conditions,
- Compact dimensions,
- Lightweight,
- 4.3" inch color IPS TFT-LCD display,
- Intuitive menu,
- Handy and easy to use,
- VFL (visual fault locator),
- LS (light source) at the OTDR wavelength with easy power adjustment,
- OPM (optical power meter) with measurement at 800~1700nm wavelengths,
- RJ45 cable length measurement capability (by connecting the cable directly to the device),
- Wire sequence measurement capability (RS - by using the RJ45 cable sequence adapter)
- Line location capability (RT - by using the wire tracker RJ45 cable tracker),
- Equipped with an Event Map to facilitate event localization.


Specification:

OTDR

Model

XB430-C1F1

XB430-C1F2

Wavelength

16550nm

1650nm

Dynamic Range

24dB

26dB

Fiber Type

SMF

Event Dead Zone

1.2m

Attenuation Dead Zone

5m

Measurement Range

500m, 1km, 2km, 4km, 8km, 16km, 32km, 64km, 100km

Measurement Pulse Width

3ns, 5ns, 10ns, 20ns, 30ns, 50ns, 80ns, 160ns, 320ns, 500ns, 800ns, 1µs, 2µs, 3µs, 5µs, 8µs, 10µs, 20µs

Ranging Accuracy

±(1m + Sample Interval + 0.005%×Test distance)

Sampling Resolution

0.05m~8m

Sampling Points

256,000 points

Linearity

≤0.05dB/dB

Loss Threshold

0.01dB

Loss Resolution

0.001dB

Range resolution

0.001m

Refracton Setting

1.00000~2.00000, 0.00001 step

Refraction Accuracy

±3dB

File Format

SOR standard file format

Laser Safety Level

Class II

Adapter

FC/UPC (Interchangeable SC adapter)


OPM

Wavelength Range (±20nm)

800~1700nm

Calibrated Wavelength

850/980/1300/1310/1490/1550/1625/1650nm

Test Range

Type A: -50~+26dBm (default); Type B: -70~+10dBm (optional)

Tone Detection

CW, 270, 330, 1k, 2kHz

Resolution

0.01dB

Uncertainty

±5%

Auto Wavelength Recoginition

Support

Connector

Universal 2.5mm (FC/SC/ST)


OLS

Emitter Type

FP-LD

Working Wavelength

Same as OTDR

Output Power

≥-5dBm

Modulation Frequency

CW/270/330/1k/2kHz

Accuracy

CW, ±0.5dB/15min (Test after 15 minutes of preheating)

Auto Wavelength Recoginition

Support

Connector

FC/UPC (Interchangeable SC adapter)

* The wavelength of Optical Light Source is the same as OTDR wavelength
* Optical Light Source shares the same fiber port as OTDR port
* Optical Light Source can run in the background, but will shut off during OTDR testing


VFL

Wavelength (±20nm)

650nm

Power

≥10mW

Mode

CW/1Hz/2Hz

Laser Safety Level

Class III

Connector

Universal 2.5mm (FC/SC/ST)

* Visual Fault Locator can run in the background


RJ45 Sequence

Test Range

300m


RJ45 Tracker

Mode

Digital tracking

Online/Line Pair Tracking

Support

Test Range

300m


Laser Distance Meters

More Information
Manufacturer Nissai
↑
Back to Top